200 sq ft
130
cfm minimum
33% of the largest published minimumFull pageThe comparison
Most comparison tables on the web invent a seventh column. This one shows the six rows EPA actually publishes, and what changes between them, in exact proportion, with nothing filled in.
The whole EPA table, compared honestly, no interpolation between rows.
Pick the rows to compare (tap to add or remove)
200 sq ft
130
cfm minimum
33% of the largest published minimumFull page400 sq ft
260
cfm minimum
67% of the largest published minimumFull pageWhat the side-by-side shows: every row works out to the same rate, 0.65 cfm per square foot. Double the room and the published minimum doubles with it. The table is one rule written six times, not six judgements.
Room
×3
Minimum CADR
+260 cfm
B over A
×3
From 200 sq ft to 600 sq ft the published minimum moves from 130 to 390 cfm, 260 cfm more, in exact proportion to the floor area. What the ratio does not capture: bigger rooms usually mean bigger machines, and bigger machines mean a louder top speed and a costlier filter. Read the noise section of the full page before you commit.
| Room area | Minimum CADR | Rate | What it fits |
|---|---|---|---|
| 100 sq ft ≈ 9.3 m² | 65 cfm | 0.65 / sq ft | A bedroom, nursery or home office. The smallest published room, and the row most boxes quietly fail. |
| 200 sq ft ≈ 18.6 m² | 130 cfm | 0.65 / sq ft | A large bedroom or small living room. Double the smallest row, twice the machine. |
| 300 sq ft ≈ 27.9 m² | 195 cfm | 0.65 / sq ft | An open kitchen-diner or a big lounge. Mid-table, where "covers 300 sq ft" claims start to wobble. |
| 400 sq ft ≈ 37.2 m² | 260 cfm | 0.65 / sq ft | A large open-plan living space. Check the tobacco-smoke CADR before anything else here. |
| 500 sq ft ≈ 46.5 m² | 325 cfm | 0.65 / sq ft | A whole floor of a small flat. Few units clear this minimum honestly. |
| 600 sq ft ≈ 55.7 m² | 390 cfm | 0.65 / sq ft | The last published row. Beyond it, nobody publishes a minimum, and this site will not invent one. |
Source: U.S. Environmental Protection Agency, Guide to Air Cleaners in the Home (2nd edition) (retrieved 2026-08-30). Assumes an 8-foot ceiling. Past 600 sq ft nothing is published, treat 390 cfm as a floor for part of the space, not a whole-room answer.
Comparing rows tells you the minimum your room clears. Which unit clears it, and how quietly, is the next decision, made from the smoke CADR and the noise section of the full page.
Moving up two rows doubles the minimum. That is the moment the machine gets bigger, the top speed gets louder and the filter gets costlier, the arithmetic makes the trade visible before you buy.
There is no seventh row to show, and no CADR column for odours. A comparison that rendered either would be decoration around a guess.
CADR is defined for particles, smoke, dust and pollen. There is no published CADR for gases, odours or VOCs, so no minimum exists for your room size. An air cleaner advertised as removing odours or VOCs is not making a claim you can compare between brands the way you can compare a particle CADR.
How the pollutant pages handle itSource: U.S. Environmental Protection Agency, Guide to Air Cleaners in the Home (2nd edition) (retrieved 2026-08-30). The published figures assume an 8-foot ceiling, if yours is higher, EPA advises choosing a higher CADR than the table shows.